Obsidian™ PA6+CF 3D Printing Filament
EFFECTIVE DATE: 08 / 01 / 2022 REVISION NUMBER: V1.1
Product Identification:
Product Name: Obsidian™ PA6+Carbon Fiber (CF)
Chemical Name: Polyamide (PA)
Recommended Use: Additive manufacturing
Supplier Information:
Rev1Tech
904 36th Street, Suite B
Grand Rapids MI 49500 USA
Phone: (616) 214-7965
Email: info@rev1tech.com
Regulation (EC) NO 1272/2008: Not classified as a dangerous product
Physical Hazards: None
OSHA Regulatory Status: This product is not considered hazardous by the 2012 OSHA Hazard Communication Standard (29 CFR 1910.1200)
Components | CAS No. | Concentration Range (%) |
---|---|---|
Polyamide Resin | Withheld as trade secret | >80 |
Carbon Fiber | 308063-67-4 | <20 |
Eyes: Flush with water. Consult physician if symptoms persist.
Skin Contact: Wash with soap and water. For thermal burns from molten polymer, immediately flush with cold water. Do not attempt to remove cooled polymer from skin. Obtain medical attention.
Inhalation: Leave exposed area and seek fresh air. If irritation persists seek medical attention.
Ingestion: Not likely due to nature of product. If ingested, drink plenty of water. Do not induce vomiting. Consult a physician if symptoms persist.
Extinguishing Media: Water spray, dry powder, and foam. Carbon dioxide (CO2)
Safety Precautions: Persons exposed to products of combustion should wear NIOSH approved self-contained breathing apparatus and full protective equipment.
Spill or release: Clean up by vacuuming or sweeping to prevent falls. If molten, allow material to cool and place into an appropriate container for disposal.
Precautions to be taken in handling and storage: Store in a dry, sprinkler equipped warehouse. Product as shipped is not a combustible dust. Mechanical handling can cause the formation of dusts. To reduce the risk for dust explosion do not permit dust to accumulate.
Waste Disposal: Dispose in accordance with applicable federal, state and local regulations.
Exposure Limits: This product does not contain any hazardous materials with occupational exposure limits established by the region-specific regulatory bodies.
Respiratory Protection: A NIOSH approved respirator is recommended for protection against processing polymeric fumes, or from dust generated from grinding, sanding, or sawing operations.
Ventilation: Local exhaust is preferred.
Protection Gloves: Canvas or cotton gloves are recommended.
Eye Protection: Safety glasses with side shields are recommended.
Other: No protective equipment is needed under normal use conditions.
Form: Solid
Appearance: Black Filament
Odor: Slight
Freezing Point: N/A
Solubility in Water: Insoluble
Specific Gravity: >1
% Volatile: N/A
Boiling Range: N/A
Vapor Pressure (MM HG): Negligible
Melting Point: This product does not possess a specific melting point. It softens gradually over a wide temperature range.
Note: Those physical data are typical values based on material tested but may vary from sample to sample. Typical values should not be construed as a guaranteed analysis of any specific lot or as specifications for the product.
Polymerization conditions to avoid: None
Chemical Stability: Stable under normal conditions
Conditions to avoid: Incompatible materials, including strong oxidizing agents
Hazardous decomposition byproducts: Thermal decomposition can yield intense heat, dense smoke, phenols, hydrogen cyanide, carbon dioxide, and carbon monoxide.
No specific toxicological information is available.
No specific ecological information is available.
Waste Disposal: Waste or unused product may be discarded in accordance with state, federal, and local regulations.
Land Transport (DOT): Non-Regulated
Sea Transport (IMDG): Non-Regulated
Air Transport (ICAO/IATA): Non-Regulated
TSCA: Complies
REACH: Complies
RoHS: Complies
EINECS/ELINCS: N/A
DSL/NDSL: Complies
PICCS: N/A
ENCS: Complies
IECSC: Complies
AICS: Complies
KECL: Complies
ROHS: Complies
REACH: Complies
Prepared by: Business Management
Issued: 08/01/2022
This information set forth herein has been gathered from standard reference materials and/or supplier test data and is, to the best knowledge and belief of Rev1Tech, accurate and reliable. Such information is offered solely for your consideration, investigation and verification, and it is not suggested or guaranteed that the hazard precautions or procedures mentioned are the only ones which exist. Rev1Tech makes no warranties, expressed or implied, with respect to the use of such information or the use of the specific material identified herein in combination with any other material or process, and assumes no responsibility therefore.