Safety Data Sheet
1. Identification
Product Name |
PolyMax™ PC-FR |
Product Use |
3D Printing Filament |
Manufacturer/Supplier |
JF Polymers (Suzhou) Co., Ltd. |
Address |
2901 Auburn Rd, Auburn Hills, MI 48326 |
Contact Email |
info@rev1tech.com |
Telephone |
+248-707-2950 |
Emergency Telephone Number |
+248-707-2950 |
2. Hazards Identification
GHS Classification
This product is not hazardous in the form in which it is shipped by the manufacturer.
GHS Label Elements
Signal word: Warning
Hazard statements: If fine particles are generated during further processing, handling or by other means, product may form combustible dust concentrations in air.
Hazardous Components: There are no hazardous components above the relevant concentration limits according to OSHA HazCom 2012.
4. First Aid Measures
Most Important Symptom(s)/Effect(s): Acute: Contact with heated material can cause thermal burns. Gases and fumes evolved during the thermal processing or decomposition of this material may irritate the eyes, skin or respiratory tract.
- Eye Contact: In case of contact, flush eyes with plenty of lukewarm water.
- Skin Contact: Cool melted product on skin with plenty of water. Do not remove solidified product. Get medical attention if thermal burn occurs.
- Inhalation: Move to fresh air in case of accidental inhalation of dust or fumes from overheating or combustion.
- Ingestion: Get medical attention.
5. Firefighting Measures
- Suitable Extinguishing Media: Water fog, Dry chemical, Carbon dioxide (CO2), Foam
- Unsuitable Extinguishing Media: High Pressure Water Streams
- Fire Fighting Procedure: Firefighters should be equipped with self-contained breathing apparatus to protect against potentially toxic and irritating fumes.
- Hazardous Decomposition Products: By Fire and Thermal Decomposition: Phenol, Carbon oxides, Hazardous decomposition products due to incomplete combustion
- Unusual Fire/Explosion Hazards: Toxic and irritating gases/fumes may be given off during burning or thermal decomposition. Avoid generating dust: fine dust dispersed in air in sufficient concentrations and in the presence of an ignition source is a potential dust explosion hazard.
6. Accidental Release Measures
- Spill and Leak Procedures: If molten, allow material to cool and place into an appropriate marked container for disposal. Sweep up and shovel into suitable containers for disposal. Dust deposits should not be allowed to accumulate on surfaces, as these may form an explosive mixture as they are released into the atmosphere in sufficient concentrations. Avoid dispersal of dust in the air (e.g., cleaning dust from surfaces with compressed air).
7. Handling and Storage
- Handling/Storage Precautions: Handle in accordance with good industrial hygiene and safety practices. Wash thoroughly after handling. Minimize dust generation and accumulation. Routine housekeeping should be instituted to ensure that dust does not accumulate on surfaces. Solid particulate can generate electrical charging during operations such as unloading from containers and pneumatic transfer. Provide adequate precautions, such as electrical grounding and bonding, where conductive equipment is involved.
- Storage Period: None.
- Storage Temperature: Maximum: 49 °C (120.2 °F)
- Storage Conditions: Containers should be tightly closed to prevent contamination with foreign materials and moisture.
- Substances to Avoid: None known.
8. Exposure Controls/Personal Protection
The recommendations in this section should not be a substitute for a personal protective equipment (PPE) assessment performed by the employer as required by 29 CFR 1910 Subpart I.
Exposure Limits
Country specific exposure limits have not been established or are not applicable
- Any component which is listed in section 3 and is not listed in this section does not have a known ACGIH TLV, OSHA PEL or supplier recommended occupational exposure limit.
Industrial Hygiene/Ventilation Measures
General dilution and local exhaust as necessary to control airborne vapors, mists, dusts and thermal decomposition products below appropriate airborne concentration standards/guidelines, especially during cutting, grinding and high heat operations.
Respiratory Protection
Although no exposure limit has been established for this product, the OSHA PEL for Particulates Not Otherwise Regulated (PNOR) of 15 mg/m3 - total dust, 5 mg/m3 - respirable fraction is recommended. In addition, the ACGIH recommends 3 mg/m3 - respirable particles and 10 mg/m3 - inhalable particles for Particles (insoluble or poorly soluble) Not Otherwise Specified (PNOS). In the event that these limits are exceeded, an air purifying respirator (APR) equipped with particulate (P100) cartridges is recommended.
Hand Protection
Ensure gloves remain in good condition during use and replace if any deterioration is observed. Wear heat resistant gloves when handling molten material.
Eye Protection
Safety glasses with side-shields
Skin Protection
No special skin protection requirements during normal handling and use.
Additional Protective Measures
Employees should wash their hands and face before eating, drinking, or using tobacco products. Educate and train employees in the safe use and handling of this product. Purgings should be collected as small flat thin shapes or thin strands to allow for rapid cooling.
9. Physical and Chemical Properties
State of Matter |
Solid |
Appearance |
Pellets |
Color |
Natural |
Odor |
Odorless |
|
Related Articles
Polymaker PC-ABS Safety Data Sheet
Safety Data Sheet 1. Identification Material Name: Polymaker™ PC-ABS Company: JF Polymers (Suzhou) Co. Ltd Address: Haicheng Industrial Park, Bldg 7, Changshu Economic Development Zone (CEDZ), Changshu, Jiangsu Province 215513, China Tel/Fax: ...
PolyMax_PC_FR Technical Data Sheet
Technical Data Sheet: PolyMax™ PC-FR Identification Product Name PolyMax PC-FR Product Use 3D Printing Filament Manufacturer/Supplier JF Polymers (Suzhou) Co., Ltd. Address 2901 Auburn Rd, Auburn Hills, MI 48326 Contact Email info@rev1tech.com ...
PolyMax™ PLA Safety Data Sheet
PolyMax™ PLA Safety Data Sheet According to Hazard Communication Standard (29 CFR 1910.1200) Version 1.0 | Issue date: 07/29/2019 | Revision date: 07/29/2019 | SDS record number: CSSS-TCO-010-132036 1. Product and Company Identification Product Name ...
Polymaker PC-ABS Technical Data Sheet
Polymaker PC-ABS Technical Data Sheet Polymaker™ PC-ABS is a PC/ABS polymer blend which offers excellent toughness and heat resistance while displaying good surface finish and good compatibility with metal plating. Physical Properties Property Test ...
PolyMax-PLA Technical Data Sheet
PolyMax-PLA Technical Data Sheet Product Identification Product Name PolyMax-PLA Product Use 3D Printing Filament Manufacturer/Supplier JF Polymers (Suzhou) Co., Ltd. Address 2901 Auburn Rd, Auburn Hills, MI 48326 Contact Email info@rev1tech.com ...