UltraCraft LED Calibration Module User Guide - Rev1Tech

LED Calibration Module User Guide

LED Calibration Module User Guide

Thank you for choosing Rev1Tech. For safety, please contact Rev1Tech support staff for assistance regarding unpacking and installing the machine. If you fail to comply with the instructions in this manual, Rev1Tech will not be liable for the consequential damages unless required by federal and local ordinances.

Please keep this operation manual properly for future reference. The pictures are for reference only and the products are subject to the actual product.

PARAMETERS

Name UltraCraft LED Calibration Module
Model UltraCraft Irradiance Meter
Probe dimensions φ38*24.5 mm
USB plug dimensions 81*38*17 mm
Length 1 m
Weight 250 g
Power 120 mW

COMPONENTS

Probe
Positioning board
USB plug

OPERATION STEPS

  1. Confirm the resin tank is well installed, empty, and clean.
  2. Connect the LED Calibration Module's USB plug to the printer's USB port.
  3. On the printer's touch screen, enter Settings > Frame energy calibration, select the quantity to calibrate, and then perform calibration following the instructions.
  4. Once calibration is done, remove the calibration module and store it properly for future use.

CAUTIONS

During calibration, keep the probe covering the round spot exactly. You may place an object with appropriate weight on the probe to keep it from moving until the spot changes its position or the calibration is finished.

Before calibration, ensure the probe is clean with no debris on its surface. If not, wipe it clean.